OpenTP1 Version 7 Messages
KFCA33203-W (E)
(aa....aa:bb....bb) The port number used for the dd....dd of cc....cc:scdmulti is outside the valid range. (starting port number = ee....ee, value specified for -m = ff....ff)
- For details about the message types and problem identification codes, see the explanation of the definition check command in the manual OpenTP1 System Definition.
- aa....aa: Message type
- bb....bb: Problem identification code
- cc....cc: Name of the definition file being checked
- dd....dd: Name of the target multi-scheduler group (specified in the -g option of the scdmulti definition command)
- ee....ee: Value specified in the -p option of the scdmulti definition command, or the start port number that is automatically determined
- ff....ff: Value specified in the -m option of the scdmulti definition command (default: 1)
- S: Continues processing.
- Countermeasure: Check and correct the specified value so that the port number does not exceed the upper limit (65535). If the -m option has been specified, correct the value so that the sum of the values specified in the -p and -m options does not exceed the upper limit (65535). If the -p option is not specified, specify either of the following values in the -p option:
- - Value of the scd_port operand + 1
- - Port number used in the previous scdmulti definition command + 1
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.