KFCA25831-E
error occurred during execution of command that starts monitored RM. name: aa...aa, reason: bb...bb, process end status: cc...cc
- An error occurred during execution of a command that starts the monitored RM.
- aa...aa: Name of the monitored RM specified in the RMM service
- bb...bb: Indicates the reason of the abnormal termination.
- PROCESS_DOWN: After the start command terminated, the monitored process failed.
- FILE_ERR: Error on the start command file
- PROCESS_ERR: Error on the process
- TIMEOUT: The command did not terminate after the monitoring time expired.
- cc...cc: Process end status (return value of wait)
- S: If the error occurred during online processing, the system fails. If the error occurred during system startup, the system takes action according to the rmm_system_behavior operand in the RMM service definition.
- O: Contact the OpenTP1 administrator.
- Countermeasure: Take countermeasures according to the cause of the error.