KFCA15566-E

mmm error occurred during alternate sending start processing. reason code=aa...aa, maintenance code1=bb...bb, maintenance code2=cc...cc, logical terminal name=dd...dd

mmm: MCF identifier
aa...aa: Reason code
00000001: The logical terminal to be used as the specified alternate origin has not been defined, or the communication service is different.
00000002: The session of the logical terminal being used as the specified alternate origin is already started.
00000003: The session of the logical terminal being used as the specified alternate origin is not yet started.
00000004: The logical terminal being used as the specified alternate origin has already requested an alternation.
00000005: The logical terminal being used as the specified alternate destination is already performing alternation.
bb...bb: Maintenance code 1
cc...cc: Maintenance code 2
dd...dd: Logical terminal name
S: Invalidates the command.
O: Take whichever of the following actions is appropriate for the displayed reason code.
00000001: Check that the name of the logical terminal specified as the alternate origin is defined in the MCF communication configuration definition. If the name has not been defined, specify a defined logical terminal. If the name has been defined, specify a logical terminal in the same communication service as the alternate origin, then re-execute.
00000002 to 00000005: Specify a logical terminal satisfying the alternate sending conditions, then re-execute.