OpenTP1 Version 7 Messages
KFCA15552-E (O)
mmm logon cannot be accepted. reason code=aa...aa
- mmm: MCF identifier
- aa...aa: Reason code
- 00000001: The logical terminal status is shut down.
- 00000002: Logon UOC returned due to an error.
- 00000003: Logon UOC rejected the logon.
- 00000004: The input format of the logon command is incorrect.
- 00000005: A parameter value specified by logon UOC is invalid.
- S: Continues processing.
- O: Take whichever of the following actions is appropriate for the displayed reason code.
- 00000001: Contact the OpenTP1 administrator.
- 00000002: Contact the OpenTP1 administrator.
- 00000003: Contact the OpenTP1 administrator.
- 00000004: Check the input format of the logon command, then re-execute.
- 00000005: Contact the OpenTP1 administrator.
- Countermeasure: Take whichever of the following actions is appropriate for the displayed reason code:
- 00000001: Release the shutdown of the logical terminal status by using the mcftactle command.
- 00000002: Remove the cause of the logon UOC being returned due to an error.
- 00000003: Remove the cause of the logon UOC rejecting the logon.
- 00000005: Check the logon UOC and specify valid values.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.