OpenTP1 Version 7 Messages
KFCA15204-E
mmm -RSP sent because invalid data was received. (aa...aa) command name=bb...bb, sense code=cc...cc
- mmm: MCF identifier
- aa...aa: Association name (of the MCF communication configuration definition (mcftalccn))
- bb...bb: Command name or data type
- SC_BIND: BIND command
- FMD_NSPE: NSPE command
- DFC_SHUTD: SHUTD command
- DFC_BID: BID command
- DFC_CANCEL: CANCEL command
- DFC_SIGNAL: SIGNAL command
- DFC_CHASE: CHASE command
- DFC_LUSTAT: LUSTAT command
- DFC_QEC: QEC command
- DFC_RELQ: RELQ command
- DFC_SBI: SBI command
- DFC_BIS: BIS command
- DFC_QC: QC command
- CMD_UNKNOWN: Unsupported command
- BROAD_FIC: Send-only FIC data
- BROAD_MIC: Send-only MIC data
- BROAD_LIC: Send-only LIC data
- BROAD_OIC: Send-only OIC data
- BROAD_DUMY: Send-only dummy data
- BROAD_DATA: Send-only dummy data (that the user assumed to be invalid)
- INQUIRY_FIC: Inquiry-response FIC data
- INQUIRY_MIC: Inquiry-response MIC data
- INQUIRY_LIC: Inquiry-response LIC data
- INQUIRY_OIC: Inquiry-response OIC data
- INQUIRY_DUMY: Inquiry-response dummy data
- INQUIRY_DATA: Inquiry-response data (that the user assumed to be invalid)
- DATA_ERR: Error data
- cc...cc: System sense code set in -RSP RU (maintenance information)
- 0x08000000: The request has not been executed because an input queue error occurred scheduling of an application was unsuccessful, or the user exit routine that edits input messages returned an error.
- 0x08090000: The mode is inconsistent. After a message with RQD specified was received, the next message was received before RSP was sent. Alternatively, a response (EB) message was received before a response, or a CANCEL command was received in a mode other than chain reception mode.
- 0x08130000: Startup of the bracket was rejected (no RTR was sent). The next message was received before RSP with RTR was received. Alternatively, a BID command was received after the send right was transferred to the host.
- 0x08140000: Startup of the bracket was rejected (RTR was sent). A message or a BID command from the host was received during the wait for RSP reception after a message was sent.
- 0x08210000: An invalid session parameter was detected during reception of a BIND command.
- 0x10020000: The RU length is invalid. The length of the receive message exceeded the maximum RU length specified in the BIND session parameter.
- 0x10030000: One of the following unsupported commands was received:
- BIS
- CHASE
- LUSTAT
- QEC
- RELQ
- SBI
- SIGNAL
- 0x20010000: The sequence is invalid. An NSPE or BIND command was received when there was no waiting for receiving a BIND command, or an SHUTD command was received more than once.
- 0x20020000: The chain status violates the rule. FIC was received more than once or together with OIC. Alternatively, MIC or LIC was received after -RSP was sent in response to receiving FIC.
- 0x20030000: The bracket violates the rule. Probable causes are:
- A response (EB) message was received during the wait for one-way reception of MIC or LIC.
- A one-way (BB or EB) message was received during the wait for reception of a response (EB) message.
- A message with BB but without EB was received from the host.
- A message without either BB or EB was received from the host.
- S: Continues processing.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.