mmm error occurred during logical screen print. reason code=aa...aa, maintenance code1=bb...bb, maintenance code2=cc...cc, connection name=dd...dd, logical terminal name=ee...ee
- mmm: MCF identifier
- aa...aa: Reason code
- 00000001: Exclusive control cannot be acquired for the printer.
- 00000002: The communication path is disconnected.
- 00000003: A printer error occurred.
- 00000004: Print service specification is invalid.
- 00000005, 00000009:
- An error occurred in XMAP3.
- 00000006: Process-specific memory is insufficient.
- 99999990 to 99999999:
- A logic conflict occurred.
- bb...bb: Maintenance code 1
- cc...cc: Maintenance code 2
- dd...dd: Connection name
- ee...ee: Logical terminal name
- S:
- When the reason code is 00000001, 00000003, 00000004, 00000005, 00000006 or 99999990:
- Continues processing.
- When the reason code is 00000009:
- Retries to establish the connection.
- When the reason code is 99999998:
- Shuts down the logical terminal.
- When the reason code is 00000002, 99999999:
- Shuts down the connection.
- O:
- When the reason code is 00000001:
- If another program is currently using the printer, wait until the end of processing and re-execute.
- When the reason code is other than 00000001:
- Contact the OpenTP1 administrator.
- Countermeasure: Take one of the following countermeasures according to the reason code:
- 00000001, 00000005, 00000006:
- Eliminate the cause of the error and re-execute.
- 00000002,00000009:
- Eliminate the cause of the error.
- 00000003: Eliminate the cause of the printer error and re-execute.
- 00000004: Correctly specify the value of the XMAP3 display and print environment file, and then re-execute.
- 99999990 to 99999999:
- Contact the maintenance personnel.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.