mmm error occurred when receiving messages. reason code=aa...aa, maintenance code1=bb...bb, maintenance code2=cc...cc, connection name=dd...dd, logical terminal name=ee...ee
- mmm: MCF identifier
- aa...aa: Reason code
- 00000001: Process-specific memory is insufficient.
- 00000002: The communication path is disconnected.
- 00000003: The receive buffer length is insufficient.
- 00000004: An invalid item is found when checking items where input is required.
- 00000005: The type of the next application, performing continuous inquiry-response, is other than cont.
- 00000006: Acquisition of the application name failed.
- 00000007: Invalid NEXT map name
- 00000008: An error occurred on input mapping.
- 00000009: An error occurred in XMAP3.
- 99999990 to 99999999: A logical conflict occurred.
- bb...bb: Maintenance code 1
- cc...cc: Maintenance code 2
- dd...dd: Connection name
- ee...ee: Logical terminal name
- S:
- When the reason code is 00000001, 00000003, 00000005, 00000008, or 99999998:
- Shuts down the logical terminal.
- When the reason code is 00000009:
- Retries to establish the connection.
- When the reason code is 00000004, 00000006, 00000007, or 99999990:
- Continues processing.
- When the reason code is 00000002, 99999999:
- Shuts down the connection.
- O: Contact the OpenTP1 administrator.
- Countermeasure: Take one of the following countermeasures according to the reason code:
- 00000001: Allocate sufficient process-specific memory and re-execute.
- 00000002, 00000008, 00000009: Eliminate the cause of the error.
- 00000003: Increase the receive buffer length of the MCF communication configuration definition and re-execute.
- 00000004: Enter all the required items and reenter the message.
- 00000005: Change the type of the next application, performing continuous inquiry-response, to cont.
- 00000006: Set the correct application name and re-execute.
- 00000007: Set the correct NEXT map name and re-execute.
- 99999990 to 99999999: Contact the maintenance personnel.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.