OpenTP1 Version 7 Messages

[Contents][Index][Back][Next]

KFCA11161-E

mmm monitoring cannot be terminated since error occurred during MHP maximum elapsed time monitoring. reason code1=aa...aa, reason code2=bb...bb

mmm: MCF identifier
aa...aa: Reason code
00000001: The monitoring request is not made using the timer ID specified by the argument. Or, the monitoring request is deleted due to a time out.
00000002: The timer service does not exist on the same node.
00000003: An error is found in the wall clock of shared memory or in the reference procedure of the time monitoring table.
00000004: The requested time monitoring information cannot be referred.
00000005: Other errors occurred.
bb...bb: Maintenance code
S: Continues processing.
O: Contact the OpenTP1 administrator.
Countermeasure: Eliminate the cause of the error described in the previous message and re-execute. If the cause is unknown, contact the maintenance personnel.