KFCA11124-E
mmm cannot activate error event. reason code1=aa...aa, reason code2=bb...bb, error event name=cc...cc name of logical terminal used for input=dd...dd
- mmm: MCF identifier
- aa...aa: Reason code
- 00000001: The error event is not defined.
- 00000002: An error occurred while referring to the application definition.
- 00000003: The logical terminal name or the internal channel is incorrect in the application definition.
- 00000004: The logical terminal for the application cannot be used.
- 00000005: The contents of the application definition and the MCF communication configuration definition do not match.
- 00000006: Memory is insufficient.
- 00000007: The region managed by the MCF cannot be accessed.
- 00000008: Impossible scheduling
- bb...bb: Maintenance code
- cc...cc: Error event name
- dd...dd: Name of the logical terminal used for input
- S: Continues processing.
- O: Contact the OpenTP1 administrator.
- Countermeasure: Eliminate the cause of the error described in the previous message and re-execute. If the cause is unknown, contact the maintenance personnel.