mmm activation of application failed. error event is activated. event-activating application name=aa...aa, application type=bb...bb, reason code=cc...cc, maintenance code=dd...dd
- mmm: MCF identifier
- aa...aa: Name of the event-activating application
- bb...bb: Type of the event-activating application
- mcf: MCF event
- user: User application
- cc...cc: Reason code
- 00000001: The maximum number of input messages that can be stored specified in the application definition was exceeded.
- 00000002: The input queue became full.
- 00000003: An I/O error occurred in the input queue.
- 00000004: An I/O error occurred in the output queue.
- 00000005: Memory is insufficient.
- 00000006: The application has been shut down.
- 00000007: The service has been shut down.
- 00000008: The service group has been shut down.
- 00000009: A logical conflict occurred.
- 00000010: The specified maximum segment length is too small. Check the specification of the segsize argument of the -e option in the mcfmuap definition command in the MCF manager definition.
- 00000011: The message length is invalid.
- 00000013: The user server is not running.
- 00000014: The SPP cannot be activated.
- 00000095: Memory is insufficient.
- 00000099: The user server is not running.
- dd...dd: Maintenance code
- S: Activates the error event processing MHP.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.