OpenTP1 Version 7 Messages
KFCA01162-E (L+E)
The aaaa(xx....xx) journal utility service cannot be started. (reason code = bbbb)
- An error occurred during startup or restart processing of the journal file service.
- aaaa: Type of journal file (Up to four alphanumeric characters)
- sys: System journal file
- xx....xx: Resource group name
- bbbb: Reason code indicating the contents of the error (Up to four numerals)
- 101: Memory is insufficient.
- 103: A network failure occurred.
- 405: An error was detected during definition analysis processing.
- 503: An error occurred during I/O processing of the status file.
- S: Terminates OpenTP1.
- O: Take action according to the reason code.
- 101: Check the memory usage.
- 103: After restoring the network, restart the system.
- 405: Check and correct the definition file. Then, restart the system. Message KFCA002xx shows the details of the error.
- 503: Investigate the cause of the error, correct the error, and restart the system.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.