OpenTP1 Version 7 Messages

[Contents][Index][Back][Next]

KFCA00821-E (L+E)

cannot place server aa...aa in shutdown state. reason code=bb...bb

An error occurred while placing the service in shutdown state.
aa...aa: Name of the server that cannot be placed in the shutdown state. (Up to eight alphanumerics)
bb...bb: Reason code indicating the contents of the error. (Up to ten numerals)
The following table shows the reason codes and countermeasures.
S: Stops processing of placing the server in the shutdown state.
O: If the server must be placed in the shutdown state, enter the scdhold command to place it in shutdown state after the OpenTP1 administrator's action.
Countermeasure: Follow the reason code.
Reason code Meaning Countermeasures
1 Invalid server name Specified server name is invalid, or the specified server is not started. For specification error, specify the correct server name and enter the scdhold command.
2 Timing error The scheduler is not started or is being terminated. Restart the system and enter the scdhold command.
3 Server is already placed in the shutdown state. Use the scdls command to check the status of the server.
4 Communication error Take countermeasures according to the error message, if any, that was output before this message. Then, enter the scdhold command.
5 Program version unmatch Check and correct the versions of OpenTP1 libraries, and enter the scdhold command.
6 Invalid server The specified server is a server that cannot be held (MHP, system server, debugger-linked server, etc.). For a specification error, specify the correct server name and enter the scdhold command.
7 Server preparing to terminate Since the specified server is now preparing to terminate, it cannot be placed in the shutdown state. If the specification is not correct, specify the server name correctly then execute the scdhold command.