OpenTP1 Version 7 Messages
KFCA00654-E (E)
The number specified for all_node in the definition file aa....aa is outside the valid range.
- No more nodes could be registered because the number of nodes specified in the domain definition file containing the all_node operand exceeded the area for the value specified in the all_node_extend_number operand in the system common definition.
- aa....aa: Name of the domain definition file containing the all_node operand
- S: Cancels command processing.
- O: Contact the OpenTP1 system administrator.
- Countermeasure: Make sure that the number of nodes specified in the domain definition file containing the all_node operand does not exceed the value of the all_node_extend_number operand. If you have modified the all_node_extend_number operand, stop and then restart OpenTP1.
All Rights Reserved. Copyright (C) 2006, 2010, Hitachi, Ltd.